VOLT 116

Vöruflokkar: , ,

The VOLT 116 is an analog input module that allows you to easily expand your Campbell Scientific data acquisition system. The VOLT 116 has 16 differential or 32 single-ended input channels and four excitation channels. It provides two 12 V ports and two switched 12 V ports for powering your peripherals, as well as four switched 5 V ports for peripheral control. The VOLT 116 features a 24-bit, analog-to-digital converter and a low-noise, analog front-end to provide you with superior analog measurements. This module also supports period average measurements and includes both current and voltage excitation channels.

Benefits and Features

  • 24-bit ADC and low-noise analog inputs
  • Channel count expansion via the CPI bus
  • Scales up the number of channels without adding measurement time
  • Easier to program than multiplexers
  • Programmable noise rejection
  • CANbus 2.0 A/B output available
  • USB 2.0 interface for PC-based operation

Specifications

Mounting Standard 1-in. grid (DIN rail mounting available)
Operating Temperature
  • -40° to +70°C (standard)
  • -55° to +85°C (extended)
Power Requirements 9.6 to 32 Vdc voltage
Estimated Accuracy
  • ±(0.04% of reading + offset) 0° to 40°C
  • ±(0.06% of reading + offset) -40° to +70°C
  • ±(0.08% of reading + offset) -55° to +85°C
Number of Channels 16 differential or 32 single-ended inputs
Analog Inputs 32 single-ended or 16 differential (with ±5000 mV, ±1000 mV, ±200 mV ranges 24 bit ADC)
Maximum Multiplexed Sample Rate 3.0 kHz (using fast [100 μs] input setting)
Maximum Burst Sample Rate 30 kHz
Input Range ±5000 mV, ±1000 mV, and ±200 mV
Period Averaging Traditional period averaging on analog input channels
CPI For data logger connection. Baud rate selectable from 50 kbps to 1 Mbps. (Allowable cable length varies depending on baud rate, number of nodes, cable quality, and noise environment, but can be as long as 700 m under proper conditions.)
USB USB 2.0 full speed connection available for attaching to a PC. (Port is used to configure the module and download updates via our Device Configuration Utility.)
Warranty One year against defects in materials and workmanship
Dimensions 20.3 x 12.7 x 5.1 cm (8 x 5 x 2 in.)
Weight 0.9 kg (1.95 lb)
Typical Current Drain
Sleep <1 mA
Active 1 Hz Scan 2 mA (estimated)

Assumes one single-ended measurement with the first notch frequency (fN1) at 30 kHz

Active 20 Hz Scan 20 mA

Assumes one single-ended measurement with the first notch frequency (fN1) at 30 kHz

Voltage/Current Excitation Outputs
Voltage Excitation ±5 V (@ 50 mA)
Current Excitation ±2.5 mA (±5 V compliance voltage)
Number of Voltage/Current Excitation Outputs 4
General Purpose Outputs
Number of SW5V Outputs 4
SW5V Output Resistance 30 Ω
Number of SW12V Outputs 2
Typical Limit of SW12V Outputs 200 mA
Minimum Limit of SW12V Outputs 180 mA
Number of 12V Outputs 2
Typical Limit of 12V Outputs 200 mA
Minimum Limit of 12V Outputs 180 mA