Compact Weather Sensor for Temperature, RH, Barometric Pressure, and Wind with Precipitation Connector and Compass
The MetSENS550 compact weather sensor measures wind speed and direction via an ultrasonic sensor, as well as air temperature, relative humidity, and barometric pressure, in a single, combined instrument mounted inside three double-louvered, naturally aspirated radiation shields with no moving parts. An integrated side connector allows users to connect a tipping bucket rain gauge. An integrated electronic compass provides apparent wind measurements. WMO average wind speed and direction and gust, temperature, relative humidity, barometric pressure, absolute humidity, air density, wet bulb temperature, rainfall total, and rainfall intensity data are provided. The MetSENS550 is compatible and easily integrated with the MeteoPV Solar Resource Platform and any Campbell Scientific data logger using SDI-12, RS-485, ModbusRS-485, or NMEA RS-232.
Benefits and Features
- Quality measurements
- Fast and simple to install
- Compact, integrated design
- Lightweight and robust
Specifications
Measurements Made |
Air temperature, barometric pressure, relative humidity, wind direction, and wind speed. (An integrated side connector allows users to connect a tipping bucket rain gauge.) |
Sampling Rate |
1 Hz |
Digital Communication Modes |
Serial RS-232, RS-422, RS-485, SDI-12, NMEA, Modbus, ASCII |
IP Rating |
66 |
Compliance |
CE, RoHS |
Operating Temperature Range |
-40° to +70°C |
Operating Voltage |
5 to 30 Vdc |
Typical Current Drain @ 12 Vdc |
- 25 mA (continuous high mode)
- 0.7 mA (eco-power mode; 1 hour polled)
|
Weight |
0.7 kg (1.5 lb) |
Air Temperature Measurement |
Measurement Range |
-40° to +70°C |
Resolution |
0.1°C |
Accuracy |
±0.3°C (@ 20°C) |
Relative Humidity Measurement |
Measurement Range |
0 to 100% |
Resolution |
0.1 |
Accuracy |
±2% @ 20°C (10 to 90% RH) |
Barometric Pressure Measurement |
Measurement Range |
300 to 1100 hPa |
Resolution |
0.1 hPa |
Accuracy |
±0.5 hPa (@ 25°C) |
Wind Speed Measurement |
Measurement Range |
0.01 to 60 m s-1 |
Accuracy |
- ±3% (up to 40 m s-1)
- ±5% (up to 60 m s-1)
|
Resolution |
0.01 m s-1 |
Starting Threshold |
0.01 m s-1 |
Wind Direction Measurement |
Measurement Range |
0° to 359° |
Accuracy |
- ±3° (up to 40 m s-1)
- ±5° (up to 60 m s-1)
|
Resolution |
1° |
Precipitation Input |
Measurement Input Type |
Triggering |
Range |
0 to 1000 mm h -1 |
Precipitation Resolution |
From 0.01 mm |
Input to MetSENS550 |
Contact closure via an M8 male, 4-pin connector. (User-supplied 20 m cable or mating female connector required.) |
Compass |
Measurement Range |
0 to 359° |
Resolution |
1° |
Units of Measure |
Degrees |
Accuracy |
±3° |