Digital Temperature and Relative Humidity Sensor with M12 Connector
The HygroVUE™10 offers a combined temperature and relative humidity element in an advanced digital sensor that is ideal for weather networks. The electronics within the sensor provide accurate measurements, and the sensor is easy to use. The digital SDI-12 output allows a simple connection and measurement by many data logging systems. Another benefit is that this digital output avoids the extra errors associated with measuring analog sensors.
A stainless-steel mesh filter on the HygroVUE™10 minimizes the effects of dust and dirt on the sensor while allowing air exchange around the sensor element and reducing the chances that condensation remains inside the filter cap. A small PTFE membrane filter is bonded to the surface of the element, which prevents any finer dust or mold from directly influencing the measurement.
Because the sensor housing is designed to withstand permanent exposure to various weather conditions and to fit inside a range of radiation shields (including compact shields), the HygroVUE™10 is truly suitable for a wide range of monitoring applications.
The HygroVUE™10 utilizes a latest-generation, Swiss-made, combined relative humidity and temperature element based on CMOSens® technology that offers good measurements, accuracy, and stability. Each element of the HygroVUE™10 is individually calibrated with the calibration corrections stored on the chip. You can easily change the sensor element in the field, which reduces your downtime and calibration costs.
Benefits and Features
- Uses a combined, pre-calibrated digital humidity and temperature element
- Field-changeable element for fast, on-site recalibration
- Digital SDI-12 output, allowing long cables with no added errors
- Simple data logger programming
- Low power consumption
- Wide operating voltage
- Rugged design with potted electronics
- Standard M12 connector with IP67 sealing rating
Specifications
Sensing Element | SHT35 modified by Campbell Scientific |
Communication Standard | SDI-12 V1.4 (responds to a subset of commands) |
Supply Voltage | 7 to 28 Vdc |
EMC Compliance | Tested and conforms to IEC61326:2013. |
Standard Operating Temperature Range | -40° to +70°C |
Main Housing Material | UV stable, white PET-P |
Electronics Sealing Classification | IP67 |
Sensor Protection | Outer glass-filled polypropylene cap fitted with a stainless-steel mesh dust filter with nominal pore size of < 30 µm. The sensor element has a PTFE protective film with a filtration efficiency of > 99.99% for particles of 200 nm or larger size. |
Sensor Connector | M12, male, 4-pole, A-coded |
Cable | Polyurethane sheathed, screened cable, nominal diameter 4.8 mm (0.19 in.) |
Sensor Cap Diameter | 12.5 mm (0.5 in.) |
Body Diameter at Connector | 18 mm (0.7 in.) |
Length | 180 mm (7.1 in.) without cable fitted |
Sensor Body Weight | 50 g (1.8 oz) |
Weight | 250 g (8.8 oz) with 5 m (16.4 ft) cable |
Relative Humidity Measurement | |
Measurement Range | 0 to 100% RH |
-NOTE- | The accuracy figures quoted are the 95% confidence limits relative to factory standards. |
Accuracy (at 25°C) |
|
Short-Term Hysteresis | < ±1% RH |
Additional Errors at Other Temperatures | < ±1% RH (over -40° to +60°C) |
Long-Term Stability | ±0.5% per year (maximum drift in clean air conditions) |
Reported Resolution | 0.001% RH |
Repeatability | 0.05% RH (3σ noise level) |
Response Time with Filter | 8 s (63% response time in air moving at 1 m/s) |
Temperature Measurement | |
Standard Measurement Range | -40°C to +70°C |
-NOTE- | The accuracy figures quoted are the 95% confidence limits relative to factory standards. |
Accuracy |
|
Long-Term Drift | < 0.03°C per year |
Reported Resolution | 0.001°C |
Repeatability | 0.04°C (3σ noise level) |
Response Time with Filter | < 130 s (63% response time in air moving at 1 m/s) |
Calibration Traceability | NIST and NPL standards |
Maximum Current Drain | |
Quiescent | 50 µA |
During Measurement | 0.6 mA (takes 0.5 s) |